Samsung Oximeter



  1. Samsung Oximeter App
  2. Samsung Oximeter Accuracy
  3. Oximeter Samsung Gear S3
  4. Samsung Health Pulse Oximeter

With the entry of Galaxy Watch 3, Samsung has unlocked some of the most-waited or most fitness centric-functions. After hearing for long from the valuable customers, the company has unlocked ECG, fall detection, SpO2, blood pressure, and VO2 max functions on the Galaxy Watch 3. Of course, few of these functions like ECG & blood pressure will land on Galaxy Watch Active 2 in the coming months. Now, in this series of guiding articles, I will cover them all and tell you how to use it. As the user of new Watch 3, you can use all these features in your country, but now, some features are available in the US & South Korea.

The other features SpO2 & VO2 Max doesn’t require any permission. You can now use them on your Galaxy Watch 3, after the installation of the first update. It is quite strange, Samsung brings these features after Garmin Fenix 6, Honor Band 5, and Huawei Band 4 Pro comes with these tools. Now, What is the Vo2 Max & SpO2? Well, these are the measurement tools that tell you how much oxygen your body has utilized during the running or workout, so it could improve the endurance. The other SpO2 or blood oxygen monitoring tells you about the effective flow of oxygen in the bloodstream.

Both of these functions are essential when you are an active workout person. The VO2 max also guides you to improve your workout age and how much you need to improve it. The same goes for Blood Oxygen sensors to keep you healthy. Now, without wasting further time. Let’s go and check out how to use SpO2 & VO2 max on Galaxy Watch 3.

  • Smartphone Users Claim Alternatives For Pulse Oximeter Give Accurate Measurement Of SpO2 According to some Samsung Galaxy users on Reddit, they have a health feature on their phones which helps them to measure blood oxygen saturation. “Most Samsung Galaxy flagship phones have a pulse oximeter built Health app Stress Measurement.
  • I just noticed that the spo2 pulse oximeter is no longer present in Samsung Health. It's not on the main screen nor is it listed in the available add-ons in the management screen. It appears to have been completely removed. Not sure when this occurred but I suspect it was after the June se.

I installed Samsung Health today (4/24/20), so I'm using the latest version. I did this explicitly to use the oxygen saturation feature. Of course I found it wasn't there; I do see the 1/22/20 notice, 'Oxygen saturation measurement is moving', which says 'In the stress tracker, if Measure multiple is turned on, your oxygen saturation level will.

Measure SpO2 on Galaxy Watch 3

1. Open Samsung Health app

When you receive the first Galaxy Watch 3 update, you will see the SpO2 feature into the Samsung Health app. Samsung Health app is already pre-installed on your watch, so open it.

2. Scroll down to the workout & health options

Samsung Oximeter

The Samsung Health app contains lots of health functions. All the features like heart rate, sleep, water, stress & breathing, weight management, women’s health tool are in the app. In that, the new option is now blood oxygen saturation.

3. Open SpO2 or Blood Oxygen option

If you don’t see the name of SpO2, Blood Oxygen, or blood oxygen monitoring, then you can tap on an icon of it. The new symbol of ‘blue waterdrop’ is the SpO2 in the Health app so open it.

Samsung Oximeter App

4. After that, tightly wear your watch on the wrist

To get better results, you have to wear your Galaxy Watch 3 on your wrist. Wear it tightly, so you get accurate results.

5. Now tap on measure

When you wear the watch appropriately, then you can real-time measure the blood oxygen saturation in your blood.

In the latest update, Samsung has added a special widget or watch face for SpO2. You can get this widget from the watch face section or download it from Galaxy Store. Set the widget and tap on the Measure button to check the results.

Measure VO2 Max on Galaxy Watch 3

It is not the app, widget, or watch face on the smartwatch. To get the VO2 max results, you have to start working out. Start activities like running, running on a treadmill, and other training to get the results. Once you complete the exercise session, then you will get your VO2 Max result. For the additional information about the results, you can go to the Samsung Health app.

Finally, you have both tools at your service. Use them on your new Galaxy Watch 3 and share your results. If you haven’t received a new firmware update on your smartwatch, then wait for a while until you receive it. Regarding this article, you can ask any questions in the comment box below.

Share this:

Related

Madhav Biradar started his career in technology back in 2011, where he covered mobile & gaming articles. He is an enthusiast in smartphone & wearable gadgets. In his free time, he likes to read about new tech gadgets and watch movies.

Related Posts

April 1, 2020

Professor Lionel Tarassenko1
Professor Trisha Greenhalgh2

On behalf of the Oxford COVID-19 Evidence Service Team
1Department of Engineering Science, University of Oxford
2Nuffield Department of Primary Care Health Sciences
University of Oxford

Correspondence to lionel.tarassenko@eng.ox.ac.uk

VERDICT

There is no evidence that any smartphone technology is accurate for the measurement of blood oxygen saturation for clinical use. Furthermore, the scientific basis of such technologies is questionable. Oxygen saturation levels obtained from such technologies should not be trusted in the clinical assessment of patients.

UPDATE
This review was updated on 19th May to take account of feedback received from academic colleagues. Whilst the feedback resulted in some minor changes to the text below, it does not change the conclusions. The feedback and our detailed response to it can be viewed here.

BACKGROUND
The COVID crisis is requiring us to manage patients with as little in-person contact as possible. The assessment of a patient with respiratory problems usually includes measurement of blood oxygen saturation (abbreviated SpO2), using a validated pulse oximeter. This is particularly important in unwell patients with COVID-19, since hypoxia is a serious warning sign for severe pneumonia.1 Whilst in-person assessment would use a standard pulse oximeter on the patient’s finger, few patients have such a technology in their homes. Various technology companies have developed smartphone apps that are marketed as accurate for measuring oxygen saturation.

A previous rapid review by our team on assessing shortness of breath in remote consultations2 turned up two academic papers which claimed to have validated smartphone technologies for measuring oxygen levels in the blood.3 4 Both papers (summarised in a table in the appendix), described comparison against a reference method (finger pulse oximetry or arterial blood gas). Whilst those papers included claims that there was good correlation between the smartphone reading and the reference standard, we were concerned about the risks of relying on these two small studies.2 We sought expert input from a Professor of Electrical Engineering (LT) who specialises in medical devices. This paper summarises Professor Tarassenko’s advice.

THE SCIENTIFIC BASIS OF OXYGEN SATURATION MEASUREMENT
Oxygen saturation is the fraction of oxygenated haemoglobin relative to the total haemoglobin (oxygenated + deoxygenated) in the blood.

SpO2 = [HbO2] / ([Hb] + [HbO2])

where HbO2 is oxygenated haemoglobin and Hb is deoxygenated haemoglobin.

The measurement of SpO2 with a pulse oximeter relies on the fact that the two forms of the haemoglobin molecule, Hb and HbO2, have light absorption properties which vary with wavelength in the visible and infra-red parts of the spectrum. It therefore requires the measurement of light transmission or reflection from a body segment such as a finger at two different wavelengths (usually in the red and infra-red).

CRITICAL APPRAISAL OF THE DIGIDOC APP TESTED BY TOMLINSON ET AL3
Despite the principles set out above, the DigiDoc app used in the Tomlinson study claims to measure oxygen saturation levels with just the flash light and camera of a smartphone. The app was reviewed in a blog on the Medpage Today website in 2015 (https://www.medpagetoday.com/blogs/iltifathusain/51888) under the headline “There are apps making unjustifiable claims, exposing patients to unnecessary risk”. The author concludes his review with the following words: “I’d urge DigiDoc to either take the app off the market until the company can support its claims or at least make significant changes to the app store description. In the meantime, clinicians […] should advise their patients not to use it.”

The claims made by DigiDoc are scientifically unsound. The app “measures oxygen saturation within 90-100% with an accuracy of 0-4 RSM compared to a medical grade oximeter”. It is not clear what RSM is (is it root root-mean-square error, RMSE?) but if we assume that they are claiming an error of ±4%, then a random number generator with a mean value of 95% and errors randomly distributed between -4% and +4% would give values between 91% and 99%.

Careful analysis of the paper by Tomlinson et al3 confirms the lack of scientific credibility for the DigiDoc app. Figure 2 in the paper (Bland-Altman plot for the SpO2 values for the DigiDoc app and the triage pulse oximeter) shows that all the readings, bar two, were between 97% and 100%, i.e. completely normal, with 95% Limits of Agreement at -4% and +3.5%. The authors observe that “reliability is low for the camera-based app, even when the two investigators tested the same patient within 1 to 2 min of each other”. Their statement that the difference between the camera-based app and the triage pulse oximeter is ±4 points should have led them to conclude, given that the x-axis in the Bland-Altman plot only extends from 96% to 100%, that the app was highly inaccurate.

CRITICAL APPRAISAL OF 2019 SCIENTIFIC ARTICLE BY DIGIDOC AND COMPUTER SCIENCE & ENGINEERING DEPARTMENT FROM SMU, DALLAS
On 19th December 2019, DigiDoc Technologies announced in a blog that a new scientific article (Measuring Oxygen Saturation with Smartphone Cameras using Convolutional Neural Networks) had been published in the November issue of the IEEE Journal of Biomedical & Health Informatics. The three authors of this paper are researcher Xinyi Ding and Associate Professor Eric C. Larson of Southern Methodist University, Dallas and the CEO of DigiDoc Technologies, Dr Damoun Nassehi.

The methodology has a number of limitations, some of which are pointed out in the paper by the authors, but which are laid out more explicitly here:

  1. The paper describes the use of a 1D convolutional neural network (CNN) for regressing oxygen saturation. According to the authors, the “bias” (the output of a low-pass filter, which is a measure of the energy of the signal) of the red photoplethysmography (PPG) signal decreases when oxygen saturation decreases. This is true, but the amplitude of the decrease will of course be different when using the app on a finger from a different individual with different skin type and different capillarity.
  2. The CNN is trained on 38 subjects and tested on just one. This is repeated 38 times, with a different test subject in each case (leave-one-out methodology). The test dataset when training a neural network should have at least 20% of the subjects, ideally 40% or 50%. Only then can one have confidence that the neural network will give accurate results on new subjects beyond those included in the original study.
  3. Pulse oximeters are calibrated to a range of oxygen saturations from 70% to 100%, with blood samples regularly drawn from the volunteers taking part in the calibration study, under medical supervision, used to obtain the reference data. In these calibration studies, the subjects are slowly de-saturated, under medical supervision, by breathing gas mixtures with reduced oxygen content (see Guazzi AR, Villarroel M, Jorge J, Daly J, Frise MC, Robbins PA, Tarassenko L. Non-contact measurement of oxygen saturation with an RGB camera. Biomedical optics express. 2015 Sep 1;6(9):3320-38). The breath holding procedure described in the DigiDoc paper is not a proper de-saturation procedure and produces very few SpO2 values below 85%. As a consequence, there is virtually no data in the 70%-85% range. From the histogram shown on Fig.9 of the paper, it is clear that the overwhelming majority of the SpO2 values are between 95% and 100%.

To summarise, the app cannot be used clinically because: (a) the training dataset does not appear to have included the full range of skin types (from Fitzpatrick skin type 1 to 6); (b) the training dataset covered a limited range of oxygen saturation values, mostly in the normal range from 95% to 100%, whereas pulse oximeters used clinically should cover the range from 70% to 100%; (c) there is no independent dataset on which the app has been tested.

Phone

In e-mail exchanges with Professor Tarassenko, Dr Larson makes a number of points:

  • Smartphone apps should not be used for monitoring COVID-19 because they are not proven accurate at lower saturation levels.
  • The statement regarding the change of skin type and capillarity is well founded.
  • A five-fold cross validation approach was also used, in which 80% of the subjects are used for training and 20% for testing (at repeated intervals such that each remaining 20% of the subject pool are used for testing – i.e. repeated cross validation). The results of the five-fold analysis were significantly no different from the leave one out results. These five-fold results were removed from the journal paper in order to meet length requirements for the journal (and because they did not change the paper’s conclusion).
  • The algorithm is most accurate above 90%. One reason for this is because of the breath-holding experimental setup, it is difficult to obtain training data below 85%.
  • As acknowledged by Ding et al., the authors of the paper never claim that their algorithm is precise enough for clinical use.

Samsung Oximeter Accuracy

In a further e-mail to Professor Tarassenko, Dr Nassehi states that “the [DigiDoc] Pulse Oximeter app is for use by sports users who are interested in knowing their blood oxygenation level (SpO2) and Heart Rate. The Pulse Oximeter app is NOT INTENDED FOR MEDICAL USE.”

CRITICAL APPRAISAL OF THE SAMSUNG APP TESTED BY TAYFUR ET AL4
The Samsung Galaxy series of phones had a red light emitting diode (LED) built into the phone in addition to the flash light and camera. There were no details released by the company of how its app used the LED to estimate oxygen saturation, but it appears from publicity material on YouTube that it worked via a single-wavelength measurement (albeit with a monochromatic light source, the LED) and therefore that oxygen saturation could not be accurately derived from it.

Samsung Oximeter

The methodology used by Tayfur and Afacan in their study is sounder than in the Tomlinson study because their reference device is an arterial blood gas (ABG) analyser. The Bland-Altman plot (Figure 4) in their paper shows that most of the oxygen saturation measurements from their Emergency Department patients were between 95% and 100%. For the few patients whose oxygen saturation measurements were between 85% and 93%, the difference between the smartphone estimate and the ABG device varied between -5.5% and +2.5%. In other words, the readings become less accurate as the patient becomes more hypoxic.

CONCLUSIONS

  • It is not physically possible to measure SpO2 using current smartphone technology.
  • The two published studies which assessed smartphone oximeter apps (Digidoc and Samsung) raise serious questions about the diagnostic accuracy.

Disclaimer: the article has not been peer-reviewed; it should not replace individual clinical judgement and the sources cited should be checked. The views expressed in this commentary represent the views of the authors and not necessarily those of the host institution, the NHS, the NIHR, or the Department of Health and social Care. The views are not a substitute for professional medical advice.

AUTHORS
Professor Tarassenko is Professor of Electrical Engineering at the University of Oxford.

Trish Greenhalgh is a Professor of Primary Care Health Sciences, co-Director of the Interdisciplinary Research In Health Sciences (IRIHS) unit, and joint module coordinator on the Knowledge Into Action (KIA) module of the MSc in Evidence Based Health Care.

Oximeter Samsung Gear S3

SEARCH (for further details see2)

We searched EMBASE and PubMed

Embase: We used the Thesaurus search builder with the terms “dyspnea” OR “hypoxia” OR “oximetry” AND “telemedicine” OR “smartphone” OR “telephone”

Pubmed: We performed the following search string using the relevant MeSH terms:

(“Oximetry”[Mesh] OR “Blood Gas Monitoring, Transcutaneous”[Mesh] OR “Dyspnea”[Mesh] OR “hypoxia”[Mesh]) AND (“Telemedicine”[Mesh] OR “Remote Consultation”[Mesh] OR “Smartphone”[Mesh] OR “Telephone”[Mesh])

APPENDIX: DETAILS OF INCLUDED STUDIES
(acknowledging Koot Kotze and Helene-Mari Van Der Westhuizen2)

Author, Title, Journal, Year, Country Aims/objectives, Study typeSampling/recruitment method, No of participantsData collection methodMain Findings
Sarah Tomlinson, Sydney Behrmann, James Cranford, Marisa Louie, and Andrew Hashikawa. Accuracy of Smartphone-Based Pulse Oximetry Compared with Hospital-Grade Pulse Oximetry in Healthy Children. Telemedicine and e-Health. Jul 2018.527-535, United States of AmericaValidation study that compared DigiDoc “a camera-based app (CBA), which utilizes the phone’s own camera lens and flash with no additional device required” and “a probe-based app (PBA), which is an app designed to use an external probe that connects directly to the smartphone. ““81 children ages 2–13 years without a respiratory complaint and a triage SpO2 ‡97% seen in a pediatric Emergency Department.”

Children were excluded if they were in the ED for a respiratory-related complaint, if they had underlying cardiac, respiratory, hematologic, or metabolic disease, if they were a trauma patient, if capillary refill time in fingers was >3 s, or if they had nail polish on their fingernails.

Two investigators obtained heart rate and SpO2 using each app. Inter-rater reliability was tested using interclass correlations (ICCs), and Bland– Altman method was used to compare app values to triage measurements.The Probe Based App (PBA) was equivalent to standard pulse oximetry (in non-hypoxic children), but the Camera Based App (CBA) that uses the phone’s camera and flash was unreliable.

“ICC for SpO2 for PBA and CBA were 0.73 and -0.24, respectively. The 95% limits of agreement between the PBA SpO2 and triage SpO2 were -2.8 to +2.5 compared with -4.1 to +3.5 for the CBA SpO2 and triage SpO2. Mean differences between triage SpO2 and the PBA SpO2 (-0.17%) and triage SpO2 and CBA SpO2 (-0.33%) were not statistically significant. “

Author,Title, Journal, Year, Country Aims/objectives, Study typeSampling/recruitment method, No of participantsData collection methodMain Findings
Tayfur I, Afacan MA. Reliability of smartphone measurements of vital parameters: A prospective study using a reference method. Am J Emerg Med 2019;37:1527–30. TurkeyThis was a study “aimed to evaluate the accuracy of HR and SaO2 data obtained using a smartphone compared with the measurements of a vital signs monitor (VSM) and an arterial blood gas (ABG) device, respectively.”Convenience sample of 114 patients presenting to an emergency unit in Istanbul. 13 results were excluded due to technical reasons. ”The data of a total of 101 patients, 48 male (47.5%) and 53 female (52.5%), were analyzed.”

“The mean age of the male and female patients was 68.08 and 72 years, respectively. According to the age distribution of the patients, the highest number of patients were in the 60–69 years group (25.75%, n=26).” 42% had pulmonary disease.

It is not noted how many patients were excluded according to pre-defined exclusion criteria, which were: “patients aged under 18 years, those that did not agree or give consent to participate in the study, those requiring urgent intervention (blue code, unstable patients), those not able to adapt to the measurements with a device (unconscious, confused, etc.), those with a high degree of hypothermia that might adversely affect the measurement from the skin, and those wearing nail polish or false nails.

“This study investigated the SaO2 and HR measurement reliability and efficacy of a Samsung Galaxy S8 (SM- G950F) smartphone… and the VSM (Welch Allyn, Connex Spot Monitor 71 WT) equipped with a Nellcor probe, and an ABG device (Radiometer ABL800, 754R0428N007), both available in the emergency service. The HR data measured by the smartphone were compared with the HR values obtained from the same VSM simultaneously. The triage nurse/paramedic measured the HR and SaO2 values using VSM and noted them in the study form. The smartphone measurements were undertaken by a second emergency service nurse blinded to the HR and SaO2 values determined by VSM and recorded in another form. The real-time ABG analysis was performed by doctors working in the emergency room on the same day and the results were noted in the ABG section of the study form.”A Bland-Altman analysis of the results comparing VSM to the smartphone for heart rate and oxygen saturation found a

Mean difference:

Smartphone SaO2 vs Arterial blood gas SaO2:

−0.67% (95%CI=−0.845 to−0.494).

Correlation coefficient:

0.968 for smartphone SaO2 – ABG SaO2 (95% CI = 0.952 to 0.978). The VSM and Smartphone SaO2 mean difference and correlation coefficient are not reported, and this is problematic as it is the most clinically useful parameter, given that this is the likely application of the study – replacing one form of non-invasive oximetry with another.

Samsung Health Pulse Oximeter

REFERENCES

  1. Greenhalgh T, Koh GCH, Car J. Covid-19: a remote assessment in primary care. Bmj 2020;368:m1182. doi: 10.1136/bmj.m1182 [published Online First: 2020/03/28]
  2. Greenhalgh T, Kotze K, Van Der Westhuizen H-M. Are there any evidence-based ways of assessing dyspnoea (breathlessness) by telephone or video? : Oxford COVID-19 Evidence Service Rapid Review. 30th March 2020. Accessed 1.4.20 at https://www.cebm.net/covid-19/are-there-any-evidence-based-ways-of-assessing-dyspnoea-breathlessness-by-telephone-or-video/.
  3. Tomlinson S, Behrmann S, Cranford J, et al. Accuracy of smartphone-based pulse oximetry compared with hospital-grade pulse oximetry in healthy children. Telemedicine and e-Health 2018;24(7):527-35.
  4. Tayfur İ, Afacan MA. Reliability of smartphone measurements of vital parameters: A prospective study using a reference method. The American journal of emergency medicine 2019;37(8):1527-30.